BAL Series
Rated 3.5/5 based on 11 customer reviews

BAL Series

Available: In Stock
Applications:
* When battery packs are remote mounted, the remote distance cannot exceed ½ the distance from ballast to lamp specified by the A.C. ballast manufacturer. The maximum allowable remote mounting distance is 50 feet. Accessories:
WARRANTY/LISTING
  • Five year warranty against defects in material and workmanship. (Lamps excluded)
  • Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes.
  • UL listed for damp locations.
Applications:
* When battery packs are remote mounted, the remote distance cannot exceed ½ the distance from ballast to lamp specified by the A.C. ballast manufacturer. The maximum allowable remote mounting distance is 50 feet. Accessories:
WARRANTY/LISTING
  • Five year warranty against defects in material and workmanship. (Lamps excluded)
  • Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes.
  • UL listed for damp locations.

Specifications

ILLUMINATION

  • Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting.
  • Operates one lamp in the emergency mode for a minimum of 90 minutes.
  • Provides a maximum initial lumen output of 750 lumens.

ELECTRICAL

  • Dual 120/277 voltage.
  • Charge rate/power “ON” LED indicator light and push-to-test switch for mandated code compliance testing.
  • 3.6V long-life, maintenance-free, rechargeable Sealed NiCd battery.
  • Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp for minimum 90-minute emergency illumination.
  • Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours.
  • AC output ensures compatibility with newer lamp technologies and helps prolong lamp life.
  • Time delay enhancement to overcome end-of-life circuit protection.

MOUNTING

  • Suitable for installation inside, on top or in remote* of the fixture.
  • Can be used in both switched and unswitched fixtures.
  • UL listed for factory or field installation.

HOUSING

  • Durable painted steel construction in white finish.
  • Provided with 2’ flex conduits on both ends.
  • Compact design fits most fluorescent fixtures.

Specifications

ILLUMINATION

  • Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting.
  • Operates one or two lamps in the emergency mode for a minimum of 90-minutes.
  • Provides a maximum initial lumen output of 1400 lumens.

ELECTRICAL

  • Dual 120/277 voltage.
  • Charge rate/power “ON” LED indicator light and push-to-test switch for mandated code compliance testing.
  • 6V long life, maintenance-free, rechargeable sealed NiCd battery.
  • Internal solid-state transfer switch automatically connectsthe internal battery to fluorescent lamp(s) for minimum 90-minute emergency illumination.
  • Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours.
  • Time delay enhancement to overcome end-of-life circuit protection.

MOUNTING

  • Suitable for installation inside, on top or in remote* of the fixture.
  • Can be used in both switched and unswitched fixtures.
  • UL Listed for factory or field installation.

HOUSING

  • Durable painted steel construction in white finish.
  • Compact design fits most fluorescent fixtures.

WARRANTY/LISTING

  • Five year warranty against defects in material and workmanship (lamps excluded).
  • Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes.
  • UL Listed for damp locations (0°C – 50°C).
  • Suitable for use in sealed and gasketed fixtures.

LAMP COMPATIBILITY

  • Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballasts.
  • Operates one or two T5, T5HO, T8, T12, T8HO, T12HO, Circular T5/T9, U-bend T8/T12, 4-Pin CFL and long CFL lamps in emergency mode. Refer to the chart on the next page for a complete list of compatible lamps.

Specifications

ILLUMINATION

  • Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting.
  • Operates one or two lamps in the emergency mode for a minimum of 90 minutes.
  • Provides a maximum initial lumen output of 3000 lumens.

ELECTRICAL

  • Dual 120/277 voltage.
  • Charge rate/power “ON” LED indicator light and push-to-test switch for mandated code compliance testing.
  • 14.4V long-life, maintenance-free, rechargeable Sealed NiCd battery.
  • Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp(s) for minimum 90-minute emergency illumination.
  • Fully automatic solid-state, two-rate charger initiates battery charging to recharge a discharged battery in 24 hours.
  • AC output ensures compatibility with newer lamp technologies and helps prolong lamp life.
  • Time delay enhancement to overcome end-of-life circuit protection.

MOUNTING

  • Suitable for installation, on top or in remote* of the fixture.
  • Can be used in both switched and unswitched fixtures.
  • UL listed for factory or field installation.

HOUSING

  • Durable painted steel construction in red finish.
  • Provided with 2’ flex conduit.